ToolAssay

Smallest wire gauge meeting NEC ampacity and voltage-drop limits, with every gau

Smallest wire gauge meeting NEC ampacity and voltage-drop limits, with every gauge compared

Answeringour last check, 2026-10-26
1 of 1checks answered this week
325 msmedian answer time
$0.01listed price per call
$0.01price it asked us

Paid test badge: not yet. The checks above are free: we call the tool without paying and read the payment request it sends back. The Verified badge needs paid calls whose answers match the promised output, and nobody can buy a badge.

Endpoint

GET https://saylorinnovations.com/api/construction/voltage-drop

CategoryEverything else
Provider hostsaylorinnovations.com
Networkseip155:137, eip155:42161, eip155:8453, solana:5eykt4UsFv8P8NJdTREpY1vzqKqZKvdp
Payment schemesexact
Self-reported calls, 30 days1 from 1 payers (the provider's figure, not ours)

Our checks, last 30 days

DayResultHTTPAskedTime
2026-10-26 valid payment request 402$0.01 325 ms

Example input (from the provider)

{
  "method": "GET",
  "queryParams": {
    "amps": "32",
    "continuous": "true",
    "length_ft": "120",
    "material": "copper",
    "max_drop_percent": "3",
    "phase": "single",
    "volts": "240"
  },
  "type": "http"
}

Promised output schema (from the provider)

{
  "$schema": "https://json-schema.org/draft/2020-12/schema",
  "properties": {
    "input": {
      "additionalProperties": false,
      "properties": {
        "method": {
          "enum": [
            "GET"
          ],
          "type": "string"
        },
        "queryParams": {
          "properties": {
            "amps": {
              "description": "required load current in amps (query)",
              "type": "string"
            },
            "continuous": {
              "description": "optional true when the load runs 3 hours or more, applies 125% sizing (query)",
              "type": "string"
            },
            "length_ft": {
              "description": "required one-way length in feet (query)",
              "type": "string"
            },
            "material": {
              "description": "optional copper or aluminum, default copper (query)",
              "type": "string"
            },
            "max_drop_percent": {
              "description": "optional voltage-drop limit, default 3 (branch circuit recommendation) (query)",
              "type": "string"
            },
            "phase": {
              "description": "optional single, three or dc, default single (query)",
              "type": "string"
            },
            "volts": {
              "description": "required system voltage, for example 120, 240, 480 or 12 (query)",
              "type": "string"
            }
          },
          "required": [
            "amps",
            "volts",
            "length_ft"
          ],
          "type": "object"
        },
        "type": {
          "const": "http",
          "type": "string"
        }
      },
      "required": [
        "type",
        "method"
      ],
      "type": "object"
    },
    "output": {
      "properties": {
        "example": {
          "type": "object"
        },
        "type": {
          "const": "json",
          "type": "string"
        }
      },
      "required": [
        "type"
      ],
      "type": "object"
    }
  },
  "required": [
    "input"
  ],
  "type": "object"
}

This page as JSON