ToolAssay

Conductor mass is calculated from nominal cross-section, core count and length a

Conductor mass is calculated from nominal cross-section, core count and length against the material density; for a nominal cross-section this is exact and independent of stranding. Total cable mass and the copper share are returned as a range derived from published manufacturer weight tables per cross-section band, not as a type-test value. Insulation, filler and armour are not modelled individually.

Answeringour last check, 2026-10-18
1 of 1checks answered this week
914 msmedian answer time
$0.002listed price per call
$0.002price it asked us

Paid test badge: not yet. The checks above are free: we call the tool without paying and read the payment request it sends back. The Verified badge needs paid calls whose answers match the promised output, and nobody can buy a badge.

Endpoint

POST https://material.halowerk.com/cable-mass

CategoryEverything else
Provider hostmaterial.halowerk.com
Networkseip155:8453
Payment schemesexact
Self-reported calls, 30 days2 from 2 payers (the provider's figure, not ours)

Our checks, last 30 days

DayResultHTTPAskedTime
2026-10-18 valid payment request 402$0.002 914 ms

Example input (from the provider)

{
  "body": {
    "cable_type": "NYM-J",
    "cores": 3,
    "cross_section_mm2": 1.5,
    "length_m": 100
  },
  "bodyType": "json",
  "method": "POST",
  "type": "http"
}

Promised output schema (from the provider)

{
  "$schema": "https://json-schema.org/draft/2020-12/schema",
  "properties": {
    "input": {
      "additionalProperties": false,
      "properties": {
        "body": {
          "additionalProperties": false,
          "properties": {
            "cable_type": {
              "description": "Cable designation, e.g. NYM-J, NYY-J, H07V-K, H05VV-F, H07RN-F, NYCWY.",
              "type": "string"
            },
            "concentric_conductor_mm2": {
              "description": "Cross-section of the concentric conductor, if present.",
              "maximum": 500,
              "minimum": 0,
              "type": "number"
            },
            "conductor": {
              "default": "copper",
              "enum": [
                "copper",
                "aluminium"
              ],
              "type": "string"
            },
            "cores": {
              "description": "Number of load-carrying cores.",
              "maximum": 61,
              "minimum": 1,
              "type": "integer"
            },
            "cross_section_mm2": {
              "description": "Nominal cross-section of one core in mm2.",
              "maximum": 1000,
              "minimum": 0.05,
              "type": "number"
            },
            "length_m": {
              "default": 1,
              "description": "Cable length in metres. Default 1.",
              "maximum": 100000,
              "minimum": 0.1,
              "type": "number"
            }
          },
          "required": [
            "cable_type",
            "cores",
            "cross_section_mm2"
          ],
          "type": "object"
        },
        "bodyType": {
          "enum": [
            "json",
            "form-data",
            "text"
          ],
          "type": "string"
        },
        "method": {
          "enum": [
            "POST",
            "PUT",
            "PATCH"
          ],
          "type": "string"
        },
        "type": {
          "const": "http",
          "type": "string"
        }
      },
      "required": [
        "type",
        "method",
        "bodyType",
        "body"
      ],
      "type": "object"
    }
  },
  "required": [
    "input"
  ],
  "type": "object"
}

This page as JSON