Auffret 2018 ORBI integer score for in-hospital cardiogenic shock after STEMI tr
Auffret 2018 ORBI integer score for in-hospital cardiogenic shock after STEMI treated by primary PCI. Rounded adjusted-OR points (max 36) from age >70, prior stroke/TIA, cardiac arrest, anterior STEMI, FMC-to-PPCI >90 min, Killip I-III, heart rate >90, SBP <125 with pulse pressure <45, glucose >10 mmol/L, left-main culprit, and post-PPCI TIMI <3. Derivation-cohort class I-IV percents. Not a medical device, not a cath-lab or shock-treatment order, and not the ORBIT bleeding score.
Paid test badge: not yet. The checks above are free: we call the tool without paying and read the payment request it sends back. The Verified badge needs paid calls whose answers match the promised output, and nobody can buy a badge.
Endpoint
POST https://api.magentlab.com/api/calc/orbi
| Category | Everything else |
|---|---|
| Provider host | api.magentlab.com |
| Networks | eip155:8453 |
| Payment schemes | exact |
| Self-reported calls, 30 days | 0 from 0 payers (the provider's figure, not ours) |
Our checks, last 30 days
| Day | Result | HTTP | Asked | Time |
|---|---|---|---|---|
| 2026-09-28 | valid payment request | 402 | $0.007 | 295 ms |
Example input (from the provider)
{
"body": {
"items": [
{
"age_years": 60,
"anterior_stemi": false,
"cardiac_arrest_on_admission": false,
"fmc_to_ppci_gt_90_min": false,
"glucose_gt_10_mmol_l": false,
"heart_rate": 70,
"killip_class": "i",
"left_main_culprit": false,
"post_ppci_timi_lt_3": false,
"prior_stroke_tia": false,
"sbp_lt_125_and_pp_lt_45": false
},
{
"age_years": 60,
"anterior_stemi": false,
"cardiac_arrest_on_admission": false,
"fmc_to_ppci_gt_90_min": false,
"glucose_gt_10_mmol_l": false,
"heart_rate": 70,
"killip_class": "i",
"left_main_culprit": false,
"post_ppci_timi_lt_3": false,
"prior_stroke_tia": false,
"sbp_lt_125_and_pp_lt_45": false
}
]
},
"method": "POST",
"type": "http"
}
Promised output schema (from the provider)
{
"$schema": "https://json-schema.org/draft/2020-12/schema",
"properties": {
"input": {
"additionalProperties": false,
"properties": {
"body": {
"additionalProperties": false,
"properties": {
"items": {
"items": {
"properties": {
"age_years": {
"description": "Age in years (18-120). Auffret 2018: older than 70 scores 2; 70 or younger scores 0.",
"type": "integer"
},
"anterior_stemi": {
"description": "Anterior ST-elevation myocardial infarction (Auffret 2018: 1 point). Caller-assigned. magent does not read the ECG.",
"type": "boolean"
},
"cardiac_arrest_on_admission": {
"description": "Cardiac arrest on admission (Auffret 2018: 3 points). true or false.",
"type": "boolean"
},
"fmc_to_ppci_gt_90_min": {
"description": "First medical contact to primary PCI greater than 90 minutes (Auffret 2018: 2 points). true or false. magent does not compute timestamps.",
"type": "boolean"
},
"glucose_gt_10_mmol_l": {
"description": "Admission glucose >10 mmol/L (Auffret 2018: 3 points). true or false. magent does not convert units.",
"type": "boolean"
},
"heart_rate": {
"description": "Heart rate in beats per minute (integer 30-220). Auffret 2018: greater than 90 scores 3.",
"type": "integer"
},
"killip_class": {
"description": "Caller-assigned Killip class after STEMI (Auffret 2018): i (0), ii (2), or iii (6). Killip IV is rejected because the derivation excluded cardiogenic shock on admission. magent does not examine the patient.",
"enum": [
"i",
"ii",
"iii"
],
"type": "string"
},
"left_main_culprit": {
"description": "Whether the culprit lesion is the left main coronary artery (Auffret 2018: 5 points). Caller-assigned. magent does not read the angiogram.",
"type": "boolean"
},
"post_ppci_timi_lt_3": {
"description": "Whether post-primary-PCI TIMI flow is <3 (Auffret 2018: 5 points). Caller-assigned. magent does not assign TIMI flow.",
"type": "boolean"
},
"prior_stroke_tia": {
"description": "Prior stroke or TIA (Auffret 2018: 2 points). true or false.",
"type": "boolean"
},
"sbp_lt_125_and_pp_lt_45": {
"description": "Whether systolic BP is <125 mm Hg and pulse pressure is <45 mm Hg together (Auffret 2018: 4 points). Single caller-assigned boolean; magent does not take separate SBP or pulse-pressure numbers.",
"type": "boolean"
}
},
"required": [
"age_years",
"prior_stroke_tia",
"cardiac_arrest_on_admission",
"anterior_stemi",
"fmc_to_ppci_gt_90_min",
"killip_class",
"heart_rate",
"sbp_lt_125_and_pp_lt_45",
"glucose_gt_10_mmol_l",
"left_main_culprit",
"post_ppci_timi_lt_3"
],
"type": "object"
},
"maxItems": 25,
"minItems": 1,
"type": "array"
}
},
"required": [
"items"
],
"type": "object"
},
"headers": {
"additionalProperties": {
"type": "string"
},
"type": "object"
},
"method": {
"const": "POST",
"type": "string"
},
"type": {
"const": "http",
"type": "string"
}
},
"required": [
"type",
"method"
],
"type": "object"
},
"output": {
"properties": {
"example": {
"type": "object"
},
"type": {
"type": "string"
}
},
"required": [
"type"
],
"type": "object"
}
},
"required": [
"input"
],
"type": "object"
}