ToolAssay

Manning 1980 fetal biophysical profile

Manning 1980 fetal biophysical profile. Five caller-assigned variables, each 2 if normal or 0 if abnormal: fetal breathing movements, fetal movements, fetal tone, qualitative amniotic fluid volume, and nonstress test. Score 0-10. 1980 breathing is a 60-second episode in 30 minutes; 1980 fluid is a 1 cm pocket. magent does not ultrasound. Not a delivery order. Does not apply later 30-second breathing, 2 cm pocket, or 8-10/6/<=4 management bands.

Asked 1.4x its listed price for its own exampleour last check, 2026-09-28
1 of 1checks answered this week
307 msmedian answer time
$0.005listed price per call
$0.007price it asked us

Paid test badge: not yet. The checks above are free: we call the tool without paying and read the payment request it sends back. The Verified badge needs paid calls whose answers match the promised output, and nobody can buy a badge.

Endpoint

POST https://api.magentlab.com/api/calc/bpp

CategoryEverything else
Provider hostapi.magentlab.com
Networkseip155:8453
Payment schemesexact
Self-reported calls, 30 days0 from 0 payers (the provider's figure, not ours)

Our checks, last 30 days

DayResultHTTPAskedTime
2026-09-28 valid payment request 402$0.007 307 ms

Example input (from the provider)

{
  "body": {
    "items": [
      {
        "fetal_breathing_movements": true,
        "fetal_movements": true,
        "fetal_tone": true,
        "nonstress_test": true,
        "qualitative_amniotic_fluid_volume": true
      },
      {
        "fetal_breathing_movements": true,
        "fetal_movements": true,
        "fetal_tone": true,
        "nonstress_test": true,
        "qualitative_amniotic_fluid_volume": true
      }
    ]
  },
  "method": "POST",
  "type": "http"
}

Promised output schema (from the provider)

{
  "$schema": "https://json-schema.org/draft/2020-12/schema",
  "properties": {
    "input": {
      "additionalProperties": false,
      "properties": {
        "body": {
          "additionalProperties": false,
          "properties": {
            "items": {
              "items": {
                "properties": {
                  "fetal_breathing_movements": {
                    "description": "Manning 1980 fetal breathing movements as assigned by the caller. true if normal: at least one episode of fetal breathing of at least 60 seconds in 30 minutes. false if abnormal: absent or no 60-second episode. Later 30-second breathing is not used. magent does not ultrasound. true or false.",
                    "type": "boolean"
                  },
                  "fetal_movements": {
                    "description": "Manning 1980 fetal movements as assigned by the caller. true if normal: at least three discrete body or limb movements in 30 minutes. false if abnormal: two or fewer. magent does not ultrasound. true or false.",
                    "type": "boolean"
                  },
                  "fetal_tone": {
                    "description": "Manning 1980 fetal tone as assigned by the caller. true if normal: at least one episode of active extension of a limb or trunk with return to flexion. false if abnormal: slow extension with return to partial flexion, limb in full extension, or absent fetal movement. magent does not ultrasound. true or false.",
                    "type": "boolean"
                  },
                  "nonstress_test": {
                    "description": "Manning 1980 nonstress test as assigned by the caller. true if normal (reactive): at least two fetal heart-rate accelerations of at least 15 bpm lasting at least 15 seconds associated with fetal movement in 20 minutes. false if abnormal (nonreactive). magent does not record cardiotocography. true or false.",
                    "type": "boolean"
                  },
                  "qualitative_amniotic_fluid_volume": {
                    "description": "Manning 1980 qualitative amniotic fluid volume as assigned by the caller. true if normal: at least one pocket of fluid measuring 1 cm in two perpendicular planes. false if abnormal: no pocket or a pocket smaller than 1 cm. Later 2 cm pocket is not used. magent does not ultrasound. true or false.",
                    "type": "boolean"
                  }
                },
                "required": [
                  "fetal_breathing_movements",
                  "fetal_movements",
                  "fetal_tone",
                  "qualitative_amniotic_fluid_volume",
                  "nonstress_test"
                ],
                "type": "object"
              },
              "maxItems": 25,
              "minItems": 1,
              "type": "array"
            }
          },
          "required": [
            "items"
          ],
          "type": "object"
        },
        "headers": {
          "additionalProperties": {
            "type": "string"
          },
          "type": "object"
        },
        "method": {
          "const": "POST",
          "type": "string"
        },
        "type": {
          "const": "http",
          "type": "string"
        }
      },
      "required": [
        "type",
        "method"
      ],
      "type": "object"
    },
    "output": {
      "properties": {
        "example": {
          "type": "object"
        },
        "type": {
          "type": "string"
        }
      },
      "required": [
        "type"
      ],
      "type": "object"
    }
  },
  "required": [
    "input"
  ],
  "type": "object"
}

This page as JSON