ToolAssay

Look up one EU aesthetic medical device in public EUDAMED data by UDI-DI, device

Look up one EU aesthetic medical device in public EUDAMED data by UDI-DI, device UUID or product name: manufacturer, risk class, EMDN code, status on record, data_as_of. 0.005 USDC per call. A no-match is charged. Empty body: free 402 with input schema. x402 v2. No certificate status. Informational.

Answeringour last check, 2026-11-26
7 of 7checks answered this week
884 msmedian answer time
$0.005listed price per call
$0.005price it asked us

Paid test badge: not yet. The checks above are free: we call the tool without paying and read the payment request it sends back. The Verified badge needs paid calls whose answers match the promised output, and nobody can buy a badge.

Endpoint

POST https://api.aestheticdata.io/x402/verify/product

CategoryCode and developer
Provider hostapi.aestheticdata.io
Networkseip155:8453
Payment schemesexact
Self-reported calls, 30 days5 from 1 payers (the provider's figure, not ours)

Our checks, last 30 days

DayResultHTTPAskedTime
2026-11-26 valid payment request 402$0.005 854 ms
2026-11-25 valid payment request 402$0.005 915 ms
2026-11-24 valid payment request 402$0.005 884 ms
2026-11-23 valid payment request 402$0.005 908 ms
2026-11-22 valid payment request 402$0.005 886 ms
2026-11-21 valid payment request 402$0.005 848 ms
2026-11-20 valid payment request 402$0.005 860 ms
2026-11-19 valid payment request 402$0.005 855 ms
2026-11-18 valid payment request 402$0.005 885 ms
2026-11-17 valid payment request 402$0.005 881 ms

Example input (from the provider)

{
  "body": {
    "product_name": "Example Filler"
  },
  "bodyType": "json",
  "method": "POST",
  "type": "http"
}

Promised output schema (from the provider)

{
  "$schema": "https://json-schema.org/draft/2020-12/schema",
  "properties": {
    "input": {
      "additionalProperties": false,
      "properties": {
        "body": {
          "additionalProperties": false,
          "properties": {
            "brand": {
              "description": "Optional. Narrows product_name. Not enough on its own.",
              "type": "string"
            },
            "manufacturer": {
              "description": "Optional. Narrows a product_name lookup.",
              "type": "string"
            },
            "product_name": {
              "description": "Product name. One equal name is exact. More than one is ambiguous. A near name is fuzzy, at most 10.",
              "maxLength": 200,
              "minLength": 1,
              "type": "string"
            },
            "udi_di": {
              "description": "UDI-DI. Send this, uuid, or product_name. One row is exact. More than one is ambiguous.",
              "maxLength": 128,
              "minLength": 4,
              "type": "string"
            },
            "uuid": {
              "description": "Device UUID, including an alias. queried_uuid echoes it. device_uuid is the stored id.",
              "type": "string"
            }
          },
          "type": "object"
        },
        "bodyType": {
          "enum": [
            "json",
            "form-data",
            "text"
          ],
          "type": "string"
        },
        "method": {
          "enum": [
            "POST",
            "PUT",
            "PATCH"
          ],
          "type": "string"
        },
        "type": {
          "const": "http",
          "type": "string"
        }
      },
      "required": [
        "type",
        "method",
        "bodyType",
        "body"
      ],
      "type": "object"
    },
    "output": {
      "properties": {
        "example": {
          "additionalProperties": false,
          "properties": {
            "attribution": {
              "type": "string"
            },
            "candidates": {
              "description": "Empty for an exact hit or no match. Every equal-name hit when match is ambiguous. At most 10 near names when match is fuzzy, highest score first.",
              "items": {
                "additionalProperties": false,
                "properties": {
                  "device_uuid": {
                    "type": "string"
                  },
                  "emdn": {
                    "properties": {
                      "code": {
                        "type": [
                          "string",
                          "null"
                        ]
                      },
                      "term": {
                        "type": [
                          "string",
                          "null"
                        ]
                      }
                    },
                    "required": [
                      "code",
                      "term"
                    ],
                    "type": "object"
                  },
                  "last_seen_at": {
                    "description": "UTC ISO-8601 of the last sync whose upstream list contained the device. Not last_changed_at.",
                    "type": [
                      "string",
                      "null"
                    ]
                  },
                  "listed_in_eudamed_public": {
                    "type": "boolean"
                  },
                  "manufacturer": {
                    "properties": {
                      "name": {
                        "type": [
                          "string",
                          "null"
                        ]
                      },
                      "srn": {
                        "type": [
                          "string",
                          "null"
                        ]
                      }
                    },
                    "required": [
                      "name",
                      "srn"
                    ],
                    "type": "object"
                  },
                  "registration_status": {
                    "enum": [
                      "listed",
                      "no_longer_listed"
                    ],
                    "type": "string"
                  },
                  "risk_class": {
                    "type": [
                      "string",
                      "null"
                    ]
                  },
                  "score": {
                    "maximum": 1,
                    "minimum": 0,
                    "type": "number"
                  },
                  "trade_name": {
                    "type": [
                      "string",
                      "null"
                    ]
                  }
                },
                "required": [
                  "device_uuid",
                  "score",
                  "manufacturer",
                  "risk_class",
                  "emdn",
                  "listed_in_eudamed_public",
                  "registration_status",
                  "last_seen_at"
                ],
                "type": "object"
              },
              "maxItems": 10,
              "type": "array"
            },
            "data_as_of": {
              "description": "UTC ISO-8601 of the last successful catalog sync.",
              "type": [
                "string",
                "null"
              ]
            },
            "device_uuid": {
              "description": "Stored device UUID. Null unless matched is true.",
              "type": [
                "string",
                "null"
              ]
            },
            "disclaimer": {
              "enum": [
                "informational, based on EUDAMED public data"
              ],
              "type": "string"
            },
            "emdn": {
              "additionalProperties": true,
              "type": [
          

This page as JSON