{"slug":"rechen-halowerk-com-v1-heat-pump-sizing-ff6ff4","title":"Heat pump sizing from the building heat load","host":"rechen.halowerk.com","method":"POST","resource":"https://rechen.halowerk.com/v1/heat-pump-sizing","category":"other","description":"Heat pump sizing from the building heat load: required output incl. hot water and utility blocking times, bivalence point from the manufacturer capacity curve, GModG hybrid share and BEG efficiency checks, annual electricity estimate. Required heating output = (design heat load + mean hot-water load","price_listed":0.003,"price_asked":0.003,"state":"answering","state_label":"Answering","checks_7d":7,"answered_7d":7,"latency_ms_median":1196,"reported_calls_30d":1,"reported_payers_30d":1,"networks":["eip155:8453"],"badge":"unverified","paid_checks_7d":0,"paid_ok_7d":0,"example_input":{"body":{"blocking_hours_per_day":2,"capacity_curve":[{"capacity_kw":5,"outdoor_c":-15},{"capacity_kw":6,"outdoor_c":-7},{"capacity_kw":7.5,"outdoor_c":2},{"capacity_kw":8.5,"outdoor_c":7}],"design_heat_load_kw":8,"design_outdoor_temp_c":-12,"hot_water":{"litres_per_day":200}},"bodyType":"json","method":"POST","type":"http"},"output_schema":{"$schema":"https://json-schema.org/draft/2020-12/schema","properties":{"input":{"additionalProperties":false,"properties":{"body":{"additionalProperties":false,"properties":{"annual_heat_demand_kwh":{"maximum":100000000,"minimum":0,"type":"number"},"blocking_hours_per_day":{"default":0,"maximum":12,"minimum":0,"type":"number"},"capacity_curve":{"items":{"additionalProperties":false,"properties":{"capacity_kw":{"maximum":10000,"minimum":0,"type":"number"},"outdoor_c":{"maximum":30,"minimum":-30,"type":"number"}},"required":["outdoor_c","capacity_kw"],"type":"object"},"maxItems":20,"minItems":2,"type":"array"},"design_heat_load_kw":{"exclusiveMinimum":0,"maximum":10000,"type":"number"},"design_outdoor_temp_c":{"maximum":5,"minimum":-30,"type":"number"},"etas_35_percent":{"maximum":400,"minimum":50,"type":"number"},"etas_55_percent":{"maximum":400,"minimum":50,"type":"number"},"heat_source":{"enum":["air","ground","water","other"],"type":"string"},"heating_limit_temp_c":{"default":15,"maximum":20,"minimum":8,"type":"number"},"hot_water":{"additionalProperties":false,"properties":{"cold_c":{"default":10,"maximum":25,"minimum":0,"type":"number"},"hot_c":{"default":50,"maximum":80,"minimum":30,"type":"number"},"litres_per_day":{"maximum":100000,"minimum":0,"type":"number"},"loss_factor":{"default":1,"maximum":3,"minimum":1,"type":"number"}},"required":["litres_per_day"],"type":"object"},"hybrid":{"additionalProperties":false,"properties":{"capacity_point_a_kw":{"maximum":10000,"minimum":0,"type":"number"},"operation":{"enum":["parallel","partly_parallel","alternative"],"type":"string"},"peak_generator_kw":{"exclusiveMinimum":0,"maximum":10000,"type":"number"}},"required":["capacity_point_a_kw","peak_generator_kw","operation"],"type":"object"},"installation_year":{"maximum":2035,"minimum":2024,"type":"integer"},"low_temperature_heat_pump":{"default":false,"type":"boolean"},"refrigerant_natural":{"type":"boolean"},"seasonal_performance_factor":{"maximum":10,"minimum":1,"type":"number"}},"required":["design_heat_load_kw","design_outdoor_temp_c"],"type":"object"},"bodyType":{"enum":["json","form-data","text"],"type":"string"},"method":{"enum":["POST","PUT","PATCH"],"type":"string"},"type":{"const":"http","type":"string"}},"required":["type","method","bodyType","body"],"type":"object"},"output":{"properties":{"example":{"type":"object"},"type":{"type":"string"}},"required":["type"],"type":"object"}},"required":["input"],"type":"object"},"history":[{"day":"2026-11-28","reachable":true,"status":402,"valid_402":true,"asked_usdc":0.003,"price_match":true,"latency_ms":1186,"error":null},{"day":"2026-11-27","reachable":true,"status":402,"valid_402":true,"asked_usdc":0.003,"price_match":true,"latency_ms":1196,"error":null},{"day":"2026-11-26","reachable":true,"status":402,"valid_402":true,"asked_usdc":0.003,"price_match":true,"latency_ms":1182,"error":null},{"day":"2026-11-25","reachable":true,"status":402,"valid_402":true,"asked_usdc":0.003,"price_match":true,"latency_ms":1330,"error":null},{"day":"2026-11-24","reachable":true,"status":402,"valid_402":true,"asked_usdc":0.003,"price_match":true,"latency_ms":1205,"error":null},{"day":"2026-11-23","reachable":true,"status":402,"valid_402":true,"asked_usdc":0.003,"price_match":true,"latency_ms":1196,"error":null},{"day":"2026-11-22","reachable":true,"status":402,"valid_402":true,"asked_usdc":0.003,"price_match":true,"latency_ms":1164,"error":null},{"day":"2026-11-21","reachable":true,"status":402,"valid_402":true,"asked_usdc":0.003,"price_match":true,"latency_ms":1178,"error":null}],"description_full":"Heat pump sizing from the building heat load: required output incl. hot water and utility blocking times, bivalence point from the manufacturer capacity curve, GModG hybrid share and BEG efficiency checks, annual electricity estimate. Required heating output = (design heat load + mean hot-water load) x 24 / (24 - blocking hours). Hot water energy per day = volume x density (Kell 1975) x 4.18 kJ/(kg K) x temperature rise.","last_updated":"2026-11-21T02:27:20.21Z","schemes":["exact"]}