{"slug":"agri-halowerk-com-v1-vertical-farm-hvac-c000be","title":"Adds lighting, equipment, people, envelope and ventilation heat flows at one sup","host":"agri.halowerk.com","method":"POST","resource":"https://agri.halowerk.com/v1/vertical-farm-hvac","category":"other","description":"Adds lighting, equipment, people, envelope and ventilation heat flows at one supplied operating point, and converts evapotranspiration into a latent moisture-removal load. It is a steady-state sizing estimate without duct losses, thermal mass, equipment curves, controls, infiltration uncertainty or ","price_listed":0.004,"price_asked":0.004,"state":"answering","state_label":"Answering","checks_7d":1,"answered_7d":1,"latency_ms_median":890,"reported_calls_30d":1,"reported_payers_30d":1,"networks":["eip155:8453"],"badge":"unverified","paid_checks_7d":0,"paid_ok_7d":0,"example_input":{"body":{"envelope_area_m2":1250,"envelope_u_value_w_per_m2k":0.42,"equipment_kw":14,"evapotranspiration_l_per_hour":48,"indoor_setpoint_c":22,"lighting_kw":82,"outdoor_temperature_c":31,"people_count":5,"sensible_heat_per_person_w":90,"ventilation_m3_per_s":1.8},"bodyType":"json","method":"POST","type":"http"},"output_schema":{"$schema":"https://json-schema.org/draft/2020-12/schema","properties":{"input":{"additionalProperties":false,"properties":{"body":{"additionalProperties":false,"properties":{"envelope_area_m2":{"maximum":100000000,"minimum":0,"type":"number"},"envelope_u_value_w_per_m2k":{"maximum":100,"minimum":0,"type":"number"},"equipment_kw":{"maximum":1000000,"minimum":0,"type":"number"},"evapotranspiration_l_per_hour":{"maximum":100000000,"minimum":0,"type":"number"},"indoor_setpoint_c":{"maximum":60,"minimum":-50,"type":"number"},"lighting_kw":{"maximum":1000000,"minimum":0,"type":"number"},"outdoor_temperature_c":{"maximum":100,"minimum":-100,"type":"number"},"people_count":{"maximum":1000000,"minimum":0,"type":"integer"},"sensible_heat_per_person_w":{"maximum":2000,"minimum":0,"type":"number"},"ventilation_m3_per_s":{"maximum":1000000,"minimum":0,"type":"number"}},"required":["lighting_kw","equipment_kw","people_count","sensible_heat_per_person_w","envelope_area_m2","envelope_u_value_w_per_m2k","outdoor_temperature_c","indoor_setpoint_c","ventilation_m3_per_s","evapotranspiration_l_per_hour"],"type":"object"},"bodyType":{"enum":["json","form-data","text"],"type":"string"},"method":{"enum":["POST","PUT","PATCH"],"type":"string"},"type":{"const":"http","type":"string"}},"required":["type","method","bodyType","body"],"type":"object"}},"required":["input"],"type":"object"},"history":[{"day":"2026-09-24","reachable":true,"status":402,"valid_402":true,"asked_usdc":0.004,"price_match":true,"latency_ms":890,"error":null}],"description_full":"Adds lighting, equipment, people, envelope and ventilation heat flows at one supplied operating point, and converts evapotranspiration into a latent moisture-removal load. It is a steady-state sizing estimate without duct losses, thermal mass, equipment curves, controls, infiltration uncertainty or psychrometric state validation.","last_updated":"2026-09-01T07:56:07.589Z","schemes":["exact"]}